Shop

ABUTMENT ALIGNMENT PIN

$0.00

Feature

  • Used for checking the parallel level of implant insertion direction.
  • Used for selecting the abutment angle.
  • Used for checking the size of internal thread in the implant when the abutment is replaced.
  • Check the internal diameter of implant in various sizes.
  • Check the internal diameter of implant placed in other dentists.
  • The internal diameter of implant in every size can be easily checked with only one kit.
Description
Abutment Alignment Pin & Easy to Screw Hole Size Check    DENTALSTUDIO
Corporation Implant System Internal
Thread Size
Nobel Biocare Branemark System MK III Groovy   (NP Ø3.3) M1.6
                                                         (RP Ø3.75 , Ø4.0) M2.0
                                                         (WP Ø5.0) M2.5
NobelSpeedy System MK III Grooovy    (NP Ø3.3) M1.6
                                                                (RP Ø4.0) M2.0
                                                                (WP Ø5.0)
                                                                (WP Ø6.0) M2.5
NobelReplace Straight Groovy MK III    (NPØ3.5) M1.8
                                                                (RP Ø4.0) M2.0
                                                                (WP Ø5.0)
NobelSpeedy System Replace   (NP Ø3.5) M1.8
                                                   (RP Ø4.0) M2.0
                                                   (WP Ø5.0 , Ø6.0)
NobelReplace Tapered   (NP Ø3.5) M1.8
                                        (RP Ø4.3) M2.0
                                        (WP Ø5.0 , Ø6.0)
Straumann Standard (RN Ø3.3 , Ø4.1 , Ø4.8) M2.0
                                           (WN Ø4.8)
Standard Plus (RN Ø3.3 , Ø4.1 , Ø4.8)
                       (WN Ø4.8)
Tapered Effect (RN Ø3.3 , Ø4.1 , Ø4.8)
3i Biomet External   (Ø3.4 , Ø4.1 , Ø5.0 ,  Ø6.0) M2.0
Zimmer
(Screw-Vent)
Screw Advent Implant   (Ø3.3 , Ø3.7 , Ø4.7) 1-72UNF
Tapered Screw Advent Implant   (Ø3.7 , Ø4.7 , Ø6.0)
 Advent Implant   (Ø3.7 , Ø4.7) 4.5 Platform
                              (Ø4.7) 5.7 Platform
Zimmer
(Swissplus)
Straight Swissplus Implant   (Ø4.1 , Ø4.8) M2.0
Tapered Swissplus Implant   (Ø3.7) 3.8 Platform 1-72UNF
                                              (Ø3.7 , Ø4.8) M2.0
Zimmer
(Spline)
Spline Twist Implant   (Ø3.75 , Ø5.0) 1-72UNF
Spline Reliance Cylinder Implant   (Ø4.0 , Ø5.0)
Astra OsseoSpeed   (3.0S) M1.4
                       (3.5S , 4.0S) M1.6
                       (4.5 , 5.0 , 5.0S) M2.0
Key ston Dental
(Life core)
PrimaConnex Tapered   (Ø3.5 , Ø4.1 , Ø5.0) M1.8
                        Straight   (Ø3.3 , Ø4.0 , Ø5.0)
RENOVA Tapered   (Ø3.75 , Ø4.5 / 4.75)
                Straight   (Ø3.75 , Ø4.5 / 4.75)
RESTORE Small Diameter   (Ø3.3) 1-72UNF
                Regular Diameter   (Ø3.75 , Ø3.75) M2.0
                Wide Diameter   (Ø5.0 , Ø6.0) M2.5
STAGE-1 RDS   (Ø3.3 , Ø4.1 , Ø4.8) M2.0
                 WDS   (Ø4.8 , Ø5.5 , Ø6.3)
MIS MISTRAL Internal Octagon System   (Ø3.75 , Ø4.1 , Ø4.8) M2.0
Mis Biocom Internal    (Ø3.3 , Ø3.75 , Ø4.2 , Ø5.0 , Ø6.0) 1-72UNF
Mis Seven Internal    (Ø3.75 , Ø4.2 , Ø5.0 , Ø6.0)
Mis Lance Internal    (Ø3.75 , Ø4.2 , Ø5.0)
Dentsply Ankylos Internal   (Ø3.5 , Ø4.5 , Ø5.5 , Ø7.0) M1.8
Xive S Internal   (Ø3.0 , Ø3.4 , Ø3.8 , Ø4.5 , Ø5.5) M1.6
Frialit Internal   ( Ø3.4 , Ø3.8 , Ø4.5 , Ø5.5 , Ø6.5)
CAMLOG COMLOG ROOT Line   (Ø3.8 , Ø4.3) M1.6
                                     (Ø5.0 , Ø6.0) M2.0
Biohorizons Maestro External Implant   (Ø4.0 , Ø5.0 , Ø6.0) M2.0
SPI Implant SPI Internal Implant (Ø3.5) M1.4
SPI Internal Implant (Ø4.5 , Ø5.0 , Ø6.0) M1.6
  1. Grab an end of the pin(A.A.P) to spin and insert to the implant inside.
  2. Ensure that the pin is not spinning without traction but accurately interlocking with the implant.
  3. Select the same size of thread if the interlocking of the implant is checked.